AirGap 150/5 corner modell
Corner placed AirGap 120/5 back flow preventer category 5 type AB is type approved according to SS-EN 1717. The installation is swift and simple. It can be placed on the floor or on the wall and uses a minimal amount of space.
Radonett AirGap 150/5 is delivered as a complete unit tested in the factory before delivery. Two pre mounted 3-phase pumps (internal), damped design solenoid valve, pressure impact absorbers, adjustment valve, tuned pressure switch and control board-operation of the assembled pumps. Internally assembled stainless-steel pump leads to a low sound level and protects the pump from the aggressive environment
Specification:
- Working pressure: 150 l/min at 5 Bar
- Max pressure out: 7,4 Bar
- Max flow out: 240 l/min
- Weight (empty): 75 kg
- Height: 1 170 mm
- Wall side 1: 495 mm
- Wall side 2: 450 mm
- Volume: 128 l
- Tank in acid-proof stain-less steel: EN 1.4404
- Water in: Solenoid valve Bürkert 5282 NC R20, 1″, hammer damped
- Water out: Adjustment valve pre-mounted R25, 1 1/4″ internal
- Controll board: Radonett
- Frequency controll: Optional: Vacon
- Alarm: Overflow and pump alarm
- Dry running protection: yes
- Pump (internal): 2 x 1,5 kW, (3-phase)
- Balancing valve: yes
- Pressure sensor: Danfoss
- Power: 3 x 400 V
- Rated current: 7 A
- Installation: On the floor or on the wall in premises with floor drain and non-freezing environment.
Product leaflet
Contact Radonett for more information and for installation manual
Back flow preventers:
AirGap 60/5
Back flow preventer category 5 type AB is type approved according to SS-EN 1717.
AirGap 60/5 corner modell
Corner placed backflow preventer category 5 type AB is type approved according to SS-EN 1717.
AirGap 60/5 Frequency controlled
Frequency controlled Radonett AirGap 60/5 back flow preventer category 5 type AB.
AirGap 75/5
Back flow preventer category 5 type AB is fitted with double pumps for extra safety and redundancy!
AirGap 120/5
Backflow preventer category 5 type AB with double pumps for extra safety and redundancy!
AirGap 120/5 corner modell
Corner modell back flow preventer category 5 type AB with double pumps for extra safety and redundancy
AirGap 120/5 frequency controlled
Frequency controlled back flow preventer category 5 type AB with double pumps for extra safety and redundancy!
AirGap 150/5
Back flow preventer category 5 type AB with double pumps for extra safety and redundancy!
AirGap 150/10
Back flow preventer category 5 type AB
AirGap 150/5 Frequency controlled
Frequency controlled back flow preventer category 5 type AB with double pumps for extra safety and redundancy!
AirGap 250/6
Back flow preventer category 5 type AB
AirGap 500/6
Back flow preventer category 5 type AB
AirGap Cabinet
AirGap Cabinet is a technical cabinet for sewage pumping stations. without superstructure.